Multi plus UPS 10-120KVA (New) - MLT \ MLM
Online UPS install
Security level 3
MLT
MULTI PLUS is a state-of-the-art uninterruptible power supply, achieving the highest possible level of on-line double-conversion performance (VFI-SS-111) as defined within IEC EN 62040-3. The UPS has been designed to protect critical information and telecommunications systems, networks, services and processes whose operation could be disrupted by poor power quality and/or breaks in their mains power supply. The sizes available include: 10, 12, 15 and 20kVA all with a three-phase input and output.
The MULTI PLUS UPS is one of the most efficient UPS available with a minimal impact on its environment and power sources.
 
MLM
MULTI PLUS is ideal for the protection of critical information and
telecommunications networks which cannot run the risk of being
powered from a power quality electrical supply. The MULTI PLUS series
is available in 10, 12, 15, 20kVA three-phase and single-phase input and
single-phase output models, with double conversion on-line technology
according to the VFI-SS-111 classification, as defined by the IEC EN
62040-3 standard.
MULTI PLUS has been designed and manufactuired using state-of-theart
technologies in order to deliver maximum protection for critical users,
a zero impact on the mains power supply and a high operating
efficiency.
The high level of flexibility at the design stage means that there is full
compatibility both with three-phase power and with single-phase sources,
thus eliminating any critical factors in the connection between UPS and
system.
 
Characteristics
ZERO IMPACT SOURCE
Multi Plus UPS are easy to install, especially on sites where there is limited power capacity available, a standby generator and potentially harmonic compatibility issues:

• low input current distortion - less than 3%
• high input power factor 0.99
• power walk-in function to achieve progressive rectifier start-up
• delayed start-up on mains power supply return

Multi Plus also performs the role of a high specification filter, protecting its power supply sources (mains or generator) from any harmonics and reactive power generated by the loads it is powering.

BATTERY CARE SYSTEM
The Multi Plus Battery Care System optimises battery performance, to help extend their working life and ensure that the UPS can deliver its full-rated back-up time when called upon in an emergency.

Battery recharge: Multi Plus is designed to work with VRLA AGM and GEL lead-acid batteries including open-vented types, in addition to Ni-Cads. Specific management features include:

• One-level recharge to meet the requirements of the most common VRLA AGM batteries
• Two voltage level recharge meeting the IU characteristic
• Restricted charging to reduce electrolyte consumption and extend the life of VRLA batteries

Temperature compensation: to avoid excessive voltage being applied to the batteries in a high ambient

Battery test: to detect performance degradation and predict battery failure.
Deep discharge protection: to prevent the batteries being discharged below a level from which they cannot be recovered (especially when discharged over long periods with very low loads).
Low AC ripple current: from a high-frequency battery charger, to ensure the batteries are not subjected to this damaging element commonly experienced with some other UPS and power supply designs.
Wide input voltage range: from a rectifier that can work down to less than 40% of its nominal supply rating (at half load), removing the need to discharge the batteries.

FLEXIBILITY
Multi Plus can be used for a wide range of applications, thanks to its configuration options, flexibility, accessories and performance levels:
• suitable for powering capacitive loads, for example Blade servers - without any reduction in active power, from 0.9 leading to 0.9 lagging
• modes of operation include: On-Line, Eco, Smart-Active and Stand-By/Off
• frequency conversion mode
• Power Share connections for priority-based load shedding when the mains power supply has failed
• cold-start facility to switch the UPS on even without a mains power supply present
• extensive back-up time options using battery extension cabinets
• optional battery cabinet temperature sensor to assist the temperature compensating charger
• optional battery chargers to optimize recharge times
• optional dual input supplies
• optional isolation transformers for Galvanic isolation and neutral connectivity

ADVANCED COMMUNICATION
Multi Plus has a large front panel graphic display providing information including: real-time measurements, operating status and alarms conditions - in five different languages
Advanced multiplatform communication, for all operating systems and network environments: PowerShield³ monitoring and shutdown software included with SNMP agent
Compatible with TeleNetGuard for the remote assistance service
RS232 or USB serial port
Three communication slots for accessories including: network adapters and volt-free contacts
REPO (Remote Emergency Power Off) to shut down the UPS remotely in an emergency
Input for connection of an auxiliary contact for an external manual bypass
Input for synchronisation with an external power source
Graphic mimic panel display for remote connection.

 